ALARM MANAGEMENT OF MEDICAL GAS PIPELINE SYSTEM.
Full bore ball valves to allow instant shut-off of main, risers or branch lines of a Pipeline system.
These are de-greased, pressure tested and blown clean. End fittings made of brass are provided to
facilitate joining with copper line pipes by brazing or soldering without damaging seal components
of valves
TECHNICAL FEATURES
- Microprocessor based digital LCD alarm
- Highly visible 7" (178 mm) LCD screen
- Pressure sensing through piezoresistive sensing Technology
- Alarms can be monitored audio-visual Touch screen operation`
- Data display at a central monitoring station Real time updating of status
- Operational parameters i.e. high and low level can` be set “in-situ” to suit requirement in an area.
- Programmable pressure unit display (bar, kg/cm &mmHg). Audio mute option.
- Designed to serve 2, 3, 4, 5 & 6 gases including Vacuum Powered by 220V AC to 24V DC external adapter
TECHNICAL SPECIFICATIONS
Conforms to | ISO |
Body | Fire retardant dust-proof CRCA 18 SWG steel enclosure (NEMA 1 Enclosure) |
Finish | Fire retardant dust-proof CRCA 18 SWG steel enclosure (NEMA 1 Enclosure) |
Mounting type | Horizontal - Surface mountable (Cover opens up horizontally) |
Enclosure dimensions | 330 × 250 × 100 (L × H × T in mm) |
Gas services | 2, 3, 4, 5 & 6 Gas including Vacuum |
Gas & Vacuum connection | NIST connection for gas input |
Power connection | External 220V AC (50 Hz) to 24V DC adapter for audio visual display |
Warning system | Microprocessor based warning module should be adjustable in-situ to set operational parameters and digital pressure unit in psi / bar or kg/cm2 |
Touch Screen Display` | Digital & illuminated touch screen display for “Normal”, “High” & “Low” with High/low alarm set point for each gas (Low only for Vacuum) service Visible display coupled with audio warning in case of preset with the provision of “Mute” audio signal for 15 minutes max |
Sensors | Fully calibrated and temperature compensated application
specific Integrated Circuit signal
conditioning (in a brass housing) Pressure Sensors a. Total Error Band: ±1.0% FSS (Full Scale Span) from -20 °C to 85 °C [-4 °F to 185 °F] b. Sensing pressure span : 60 mbar to 10 bar [ 1 psi to 150 psi] Digital Output c. Temperature span : -30 °C to 50 °C [-22 °F to 122 °F] |
Information & Control` | The information of alarm, current status & test conditions through “Touch Screen” |
Display & Audio blocker | Provision to block display & audio signal of a particular supply line for long service period is builtin |
Earthling | Protective earth |
Protection | Class II & IP54 |
Certifications | ISO 13485 : 2016 - Medical devices -
Quality Management Systems ISO 9001 : 2015 - Quality Management Systems Pressure Equipment Directive 2014/68/EU |