Protection enabled. Digital Gas Alarm Unit – Alfa medico product G-F86WCBZV7P

ALARM MANAGEMENT OF MEDICAL GAS PIPELINE SYSTEM.

digital flow care
Full bore ball valves to allow instant shut-off of main, risers or branch lines of a Pipeline system.
These are de-greased, pressure tested and blown clean. End fittings made of brass are provided to
facilitate joining with copper line pipes by brazing or soldering without damaging seal components
of valves

TECHNICAL FEATURES


  • Microprocessor based digital LCD alarm

  • Highly visible 7″ (178 mm) LCD screen

  • Pressure sensing through piezoresistive sensing Technology

  • Alarms can be monitored audio-visual Touch screen operation`

  • Data display at a central monitoring station Real time updating of status

  • Operational parameters i.e. high and low level can` be set “in-situ” to suit requirement in an area.

  • Programmable pressure unit display (bar, kg/cm &mmHg). Audio mute option.

  • Designed to serve 2, 3, 4, 5 & 6 gases including Vacuum Powered by 220V AC to 24V DC external adapter

TECHNICAL SPECIFICATIONS

Conforms to ISO
Body Fire retardant dust-proof CRCA 18 SWG steel enclosure (NEMA 1
Enclosure)
Finish Fire retardant dust-proof CRCA 18 SWG steel enclosure (NEMA 1
Enclosure)
Mounting type Horizontal – Surface mountable (Cover opens up horizontally)
Enclosure dimensions 330 × 250 × 100 (L × H × T in mm)
Gas services 2, 3, 4, 5 & 6 Gas including Vacuum
Gas & Vacuum connection NIST connection for gas input
Power connection External 220V AC (50 Hz) to 24V DC adapter for audio visual
display
Warning system Microprocessor based warning module should be adjustable
in-situ to set operational parameters and digital pressure unit in
psi / bar or kg/cm2
Touch Screen Display` Digital & illuminated touch screen display for “Normal”, “High” &
“Low” with High/low alarm set point for each gas (Low only for
Vacuum) service Visible display coupled with audio warning in
case of preset with the provision of “Mute” audio signal for 15
minutes max

Sensors Fully calibrated and temperature compensated application
specific Integrated Circuit signal
conditioning (in a brass housing) Pressure Sensors
a. Total Error Band: ±1.0% FSS (Full Scale Span)
from -20 °C to 85 °C [-4 °F to 185 °F]
b. Sensing pressure span : 60 mbar to 10 bar [
1 psi to 150 psi] Digital Output
c. Temperature span : -30 °C to 50 °C [-22 °F to 122 °F]
Information & Control` The information of alarm, current status & test conditions
through “Touch Screen”
Display & Audio blocker Provision to block display & audio signal of a particular supply
line for long service period is builtin
Earthling Protective earth
Protection Class II & IP54
Certifications ISO 13485 : 2016 – Medical devices –
Quality Management Systems
ISO 9001 : 2015 – Quality Management Systems
Pressure Equipment Directive 2014/68/EU